<LOGO>
FM Transmitter Measurement Report
Created: 2026-01-27 02-57-22
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
89.40 MHz 5/5, 43 dBuV ISKELMA
Pilot RDS Phase Difference
6.4 kHz 3.7 kHz -82 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
15 kHz 71 kHz 19195 0,0417
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
4,6 dBr 5,76 dBr 6,4 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"ISKELMA " 62AD 9 (Varied) 1 0 1 1 --:--
RT
-
AF EON
89.4, 92.5, 95.0, 100.1 MHz -
FM Scope Max at: 71 kHz MIN: 15 kHz % above 76 kHz: 0,0417 Acquired: 2026/01/27 2.56.17 Total samples: 19195 Equivalent time: 0:15:59 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000 3000
FM Scope MAX: 6,4 dBr MIN: 4,6 dBr AVE: 5,76 dBr % above 12,2 dBr: 0,0 Last value: 5,8 dBr (2026/01/27 2.56.17) 02.42 02.44 02.46 02.48 02.50 02.52 02.54 02.56 0 2 4 6 Pm [dBr]